mpb datasheet mpb note tecniche

» MEASUREMENT AND TEST INSTRUMENTATION » ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS » D-8862

  

GET YOUR QUOTE

Main Category:

MEASUREMENT AND TEST INSTRUMENTATION

Secondary Category:

ELECTRIC, MAGNETIC AND ELECTROMAGNETIC FIELD METERS

Specification

Campo Elettrico: No

Campo Magnetico: No

Campo Elettromagnetico: Sì

Status:

AVAILABLE

Brand:

NARDA PMM

Model Name:

D-8862

Item Code:

NARDA PMM D-8862 NARDALERT XT DB

Applications:

Measures Work Environments EMF
Environmental measures EMF RF

Description:

Electromagnetic gauge field staff without embedded data logger. Frequency range 100 kHz - 100 GHz in measurement technology Shaped according to the Standard AS / NZ 2772.1 (1998 draft) workers, BGV B11, 2001, EXP.1 workers; ENV 50166-2 workers ICNIRP 1998 workers. Complete with belt attachment, plastic, batteries and calibration certificate.

General Features:

Two alarm thresholds can be set (default is the first 50% of the standard, and the second at 200% of the standard) to program them separately within the range 10% - 100% and 20% - 200% you need the software kit
Vibrating alarm can be set and not identical to the first alarm
5-LED 10%, 20%, 50%, 100% and 200% of the Standard AS / NZ 2772.1 (1998 draft) workers, BGV B11, 2001, EXP.1 workers; ENV 50166-2 workers ICNIRP 1998 employees equivalent power density
Capture every 5 seconds (default) or in the range of 1 sec. - 6 min (step 1 sec to 59 sec, 0.5 min to 6 min) with final results averaged over time to set logging
Sensors: A combination of diode technology (UHF) and microwave technology for the thermocouple.
Battery-powered No. 01 AA Alkaline lasting 1500 hours (alarms and LEDs off)
Recommended calibration interval: 36 months
Capture mode: max hold, instantaneous (average 1 sec), Media Program

Specifications:

Max applicable level (CW): 3000% of Standard
Max applicable level (Peak): 32 dB beyond the Standard
Immunity to electric fields Low Frequency (50/60 Hz): 6 kV / m
Operating Temperature Range: -10 ° C to +55 ° C
Storage Temperature Range: -20 ° C to +55 ° C
Dimensions: 10.5 x 7.6 x 3.5 cm
Weight: 157 g (with battery)

Associated Courses:

RADIO FREQUENCY ELECTROMAGNETIC FIELDS: environmental monitoring techniques
UNCERTAINTIES IN MEASURING EQUIPMENT

MORE INFORMATION

Related Articles: 1

mpb 8865.jpg

NARDA PMM 8865 NARDALERT XT DB

SOFTWARE

Interface Kit for portable measurements Nardalert XT consists of software for remote control interface module for the PC and XT form interface Nardalert

There are no services associated with this product