Continuous monitoring station by a large band of electric fields, magnetic and electromagnetic fields from 10 Hz to 7 GHz (depending on the probe) without solar-powered battery Lithium long life, no modem GSM / GPRS
General Features:
Available in various field probes as needed. Direct sensor input connector standard Narda
Manual discharge data to the PC via RS232 interface
Security Alarms: microswitch tamper switch, internal over-temperature, low battery, sondaguasta.
Dimensions: 60 x 780 (diameter x height) mm
Weight: 2.4 Kg
Replaceable lithium battery 3.6 V, 13 A / h
IP54
Operating temperature: -10 to + 50 ° C
Specifications:
Automatic Generation of TXT file on each dowload made
Automatic self-test during power
Dynamic depending on the probe used
Scope of work: Electric from 0.02 V / m - 200 V / m from 50 nT Magnetic - 200 mT
Resolution: Electric 0.01 V / m; 1 nT magnetic
Sensitivity-dependent probe
Accuracy: Probe dependent
Unit of measurement: V / m; nT; mT
Measuring range: X, Y, Z and total Max, AVG, RMS
Sampling: X, Y, Z every 3 sec
Interval: 15 min 30 sec
Maximum time of acquisition: With probe 1 and 3-band: 338 days with 15 min retention interval, 11 days with 30 sec interval memorizzazzione. Probe 4-band: 169 days with 15 min retention interval, 5 days with 30 sec interval memorizzazzione
Data Download: Manual PC
Functions: AVG, RMS, peak, recording temperature and battery voltage
Alarms: Two programmable thresholds (threshold of concern and alarm) and automatic alert of overcoming them that their re-entry within
Probe for the measurement of the electrical component of the electromagnetic field in 3 frequency range 100 kHz - 3 GHz, 100 kHz-862 MHz, 933 MHz - 3 GHz The sensor can be engaged only on the ECU Mod 8057